AORXI Homelab
Hardware

Per-Site Inventory

Authoritative per-node hardware inventory for Site A and Site B: model, board, RAM, onboard NICs, add-in NICs, boot drive, IPMI, and primary role.

Physical hardware inventory for every node at both sites. Each entry covers the host's chassis model, board (where specified), RAM, onboard NIC layout, add-in NIC, boot drive, IPMI, and primary role. For pool-level details see NIC Allocation and RAM & Storage Allocation.

Site A

Site A hosts four physical Proxmox nodes on 10.10.0.0/16: an edge appliance, two ThinkPad workers, and a large storage/infra server.

Compute and Storage Nodes

HostnameModelBoardRAMBootIPMIPrimary Role
sa-edge-01SYS-E200-8D64 GB (2×32 GB DDR4 RDIMM)512 GB NVMe M.2yesOPNsense VM (sa-fw-01), WireGuard, edge utilities
sa-cmp-01ThinkPad P51internal laptop drivenoDev / CI / light VMs
sa-cmp-02ThinkPad P52internal laptop drivenoGPU / AI / media / build / light VMs
sa-stor-015049A-TX11SPA-T96 GB (6×16 GB DDR4-2933 ECC RDIMM)existing boot driveyesZFS, Proxmox Backup Server (PBS-A), DNS (sa-dns-01), monitoring, databases

ThinkPads (sa-cmp-01, sa-cmp-02) use laptop-grade RAM incompatible with the DDR4 ECC RDIMM pool. Exact ThinkPad RAM capacity is unspecified in current sources.

Site A NIC Layout

HostnameOnboard NICsAdd-in NIC
sa-edge-012×10GBASE-T, 2×1GbE, dedicated IPMI LANnone
sa-cmp-01built-in 1GbE (model unspecified)1×Intel X550-T2 (dual-port; 1 port in use)
sa-cmp-02built-in 1GbE (model unspecified)1×Intel X550-T2 (dual-port; 1 port in use)
sa-stor-011×1GbE Intel i210 (red RJ45, Proxmox mgmt), 1×10GBASE-T Aquantia AQC107, dedicated IPMI LANXL710/X710-class quad-port 10GBASE-T

sa-stor-01 — AQC107 not suitable for critical traffic

The onboard Aquantia AQC107 (atlantic driver) on sa-stor-01 is historically unstable under Linux/Proxmox. Do not use it for Proxmox management or Corosync. Management runs on the Intel i210 (1GbE, red RJ45); Corosync runs tagged on the XL710 add-in card. The AQC107 is reserved for non-critical data or left unused.

Site A Networking Hardware

DeviceHostnameModelRoleNotes
Core switchsa-sw-01Netgear XS716T10 Gb L2 coreCarries Proxmox mgmt, Corosync, VM, K8s, storage, and backup VLANs. L2 only — no routing.
Access switchsa-sw-02Access / IPMIUplinks to sa-sw-01 port 15F via SFP+ DAC. Serves sa-edge-01 and sa-stor-01 mgmt + IPMI.
Access switchsa-sw-03Access / APUplinks to sa-sw-01 port 16F via SFP+ DAC. Serves sa-cmp-01, sa-cmp-02 mgmt, and sa-ap-01.
WiFi APsa-ap-01UniFi U7 Pro XGSWiFi 7 access pointsa-sw-03 port 3; 10G RJ45, PoE++ 802.3bt (~29 W); native VLAN 10, tagged VLANs 100/110/120.
Fallback routerUniFi Gateway MaxBootstrap / fallbackKept for existing WiFi / user-device continuity. Double-NAT through OPNsense is intentional.

Site B

Site B hosts six physical Proxmox nodes on 10.20.0.0/16: an edge appliance and five 1U Supermicro servers dedicated to Ceph and Kubernetes/OpenShift.

Compute Nodes

HostnameModelBoardRAMBootIPMIPrimary Role
sb-edge-01SYS-E200-8D64 GB (2×32 GB DDR4 RDIMM)512 GB NVMe M.2yesOPNsense VM (sb-fw-01), WireGuard, edge utilities
sb-cmp-01SYS-5019D-4C-FN8TP96 GB (3×32 GB DDR4 RDIMM)512 GB NVMe M.2yessb-pve cluster create node, Ceph MON/MGR, K8s control-plane
sb-cmp-02SYS-5019D-4C-FN8TP96 GB (3×32 GB DDR4 RDIMM)512 GB NVMe M.2yesCeph MON/MGR, K8s control-plane
sb-cmp-03SYS-5018D-FN4T96 GB (3×32 GB DDR4 RDIMM)512 GB NVMe M.2yesCeph / K8s worker, Kafka / build / storage
sb-cmp-04SYS-5018D-FN4T64 GB (2×32 GB DDR4 RDIMM)512 GB M.2 (NVMe or SATA)yesCeph / K8s worker
sb-cmp-05SYS-5018D-FN4T64 GB (2×32 GB DDR4 RDIMM)Micron 1300 512 GB SATA M.2yesCeph / K8s worker

Site B NIC Layout

HostnameOnboard NICsAdd-in NIC
sb-edge-012×10GBASE-T, 2×1GbE, dedicated IPMI LANnone
sb-cmp-012×10GBASE-T, 2×10G SFP+, 4×1GbE, dedicated IPMI LAN1×Intel X710-T4 (4-port 10G)
sb-cmp-022×10GBASE-T, 2×10G SFP+, 4×1GbE, dedicated IPMI LAN1×Intel X710-T4 (4-port 10G)
sb-cmp-032×10GBASE-T, 2×1GbE, dedicated IPMI LAN1×Intel X710-T4 (4-port 10G)
sb-cmp-042×10GBASE-T, 2×1GbE, dedicated IPMI LAN1×Intel X710-T4 (4-port 10G)
sb-cmp-052×10GBASE-T, 2×1GbE, dedicated IPMI LAN1×Intel X710-T4 (4-port 10G)

FN8TP onboard NIC layout — verify before cabling

The sb-cmp-01 / sb-cmp-02 (SYS-5019D-4C-FN8TP) onboard NIC layout (2×10GBASE-T, 2×10G SFP+, 4×1GbE) is listed as confirmed in CLAUDE.md (2026-06-06) but remains flagged as assumed in vault/homelab_hardware_by_site.md from the same date. Verify against physical hardware before finalizing port-map cabling. The FN4T layout (2×10GBASE-T, 2×1GbE) is confirmed in both sources.

Site B NIC Port Assignment

The X710-T4 four-port card follows this VLAN assignment on all Site B nodes (FN8TP and FN4T):

X710-T4 PortVLAN Assignment
p130 VM Services
p240 / 50 Kubernetes Nodes / K8s LB
p360 Storage / Ceph public
p490 Backup / Replication

Onboard 1G #1 carries 20 Proxmox Management; onboard 1G #2 carries 25 Corosync heartbeat (dedicated, no GW); onboard 10GBASE-T carries 65 Ceph cluster (no GW). IPMI connects to sb-sw-02 on VLAN 10.

Site B Networking Hardware

DeviceHostnameModelRoleNotes
Core switchsb-sw-01Netgear XS748T10 Gb L2 coreCarries Proxmox mgmt, Corosync, VM, K8s, Ceph storage, and backup VLANs. L2 only — no routing.
Access switchsb-sw-02UniFi USW 24 PoEAccess / AP / PoEHandles IPMI (VLAN 10), access-side clients, APs, and PoE devices.
Fallback routerUSG ProBootstrap / fallbackKept for existing network continuity. Not the infrastructure router.

On this page